| Symbols |
Items |
Meaning |
| I OMAX |
Maximum
load current |
The
effective Value of the maximum current that can
continuously flow into the output terminals under
specified cooling conditions. |
| V DRM |
Repetitive
peak off-state voltage
|
Maximum
voltage with repeatability that can be applied
continuously between the output terminals. |
| I SURGE |
Non-repetitive
surge current
|
Maximum
current without repeatability,that is based on
designated conditions. Normally this is expressed
as the wave height value of one power frequency
current sinusoidal cycle. |
| f |
Frequency |
Frequency
of power supply. |
| V IMAX |
Maximum
input voltage
|
Maximum
input voltage across the SSR input terminals.
|
| R IN |
Input
impedance |
Resistance
of current limiting resistor used in the SSR input
side. |
| V ISO |
Dielectric
strength
|
The
effective AC voltage that the SSR com withstand
when it is applied between the input terminals
and output terminals or
I/O terminals and metal housing (heat sink) for
more than laminate. |
| R ISO |
Insulation
resistance
|
The
resistance between the input and output terminals
or I/O terminals and metal housing (heat sink)
when DC voltage is imposed.
|
| T OPR |
Operating
temperature
|
Ambient
temperature range over which the SSR operates
normally under the specified heat dissipation
and load current
conditions. |
| T STG |
Storage
temperature
|
Ambient
temperature range over which the SSR can be safely
stored for extended periods without sustaining
damage or performance degradation. |
| V O |
Load
voltage range
|
Output
supply voltage range in which the SSR operates
normally, AC voltage is specified in RMS units. |
| I LEK |
Off
state leakage current
|
Current
that flows in the SSR output circuit when the
specified supply voltage is applied to the output
with no input voltage applied. |
| V SAT |
On
state voltage drop |
Output
voltage drop caused by a specified load current
supplied to the SSR output which is turned on
by a specified input voltage . AC voltage is specified
in RMS units. |
| I OMIN |
Minimum
load current |
Minimum
load current at and above which the SSR operates
normally under the specified temperature conditions.
AC current is specified in RMS units. |
| V I |
Input
voltage range |
The
permissible voltage range with in which the voltage
of on input signal voltage may fluctuate. |
| V P |
Pick
up voltage |
Minimum
input voltage when the output status changes from
ON to OFF. |
| V D |
Drop
out voltage |
Maximum
input voltage when the output status changes from
ON to OFF. |
| T ON |
Turn
on time |
Time
until the SSR output turns on after Time until
the SSR output turns on after the specified input
voltage is applied. |
| T OFF |
Turn
off time |
Time
until the SSR output tarns off after the specified
input voltage is removed |
| C IO |
Capacitance
input to output |
Capacitance
between the input and output terminals |
| - |
Zero
cross |
A
function which starts operation with the AC load
voltage at close to Zero-phase |